Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Has the HVAC Air Delivery System Check been performed? | -- | Go to Step 2 | |
2 |
Is battery voltage present? | -- | Go to Step 3 | Go to Step 10 |
3 |
Is battery voltage present? | -- | Go to Step 5 | Go to Step 4 |
4 | Repair the open in CKT 1614 (DK GRN) between the HVAC control module and the recirculation door motor. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
5 | Connect a DMM (volts) between the recirculation door motor connector, cavity 5, and the ground. Is battery voltage present? | -- | Go to Step 7 | Go to Step 6 |
6 | Locate and repair the open in CKT 141 (BRN) between splice S243 and the recirculation door motor. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
7 | Connect a DMM (continuity) between the recirculation door motor connector, cavity 7, and ground. Is continuity present? | -- | Go to Step 9 | Go to Step 8 |
8 | Locate and repair the open in CKT 150 (BLK) between the recirculation door motor and splice S244. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
9 |
Is the repair complete? | -- | -- | |
10 |
Is battery voltage? | -- | Go to Step 11 | Go to Step 12 |
11 | Replace the HVAC control module. Refer to Control Assembly Replacement . Is the repair complete? | -- | -- | |
12 | Locate and repair the open in CKT 141 (BRN) between splice S268 and the HVAC control module. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- |