Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the SIR Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Is the voltage less than the specified value? | 4-5 volts | Go to Step 4 | Go to Step 3 |
3 | Is the voltage greater than the specified value? | 4-5 volts | Go to Step 6 | |
4 |
Is continuity present? | -- | Go to Step 5 | Go to Step 8 |
5 | Locate and repair the short to ground in CKT 800 (TAN) between the sensing and diagnostic module (SDM) and the DLC. Refer to SIR/SRS Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
6 |
Is the voltage greater than the specified value? | 0 volts | Go to Step 7 | Go to Step 8 |
7 | Locate and repair the short to voltage in CKT 800 (TAN) between the sensing and diagnostic module (SDM) and the DLC. Refer to SIR/SRS Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
8 | Perform the SDM integrity check. Refer to Sensing and Diagnostic Module Integrity Check in SIR. Did the SDM pass the check? | -- | Go to Step 9 | |
9 | Replace the SDM. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement in SIR. Is the repair complete? | -- | -- |