Table 1: | Auxiliary Blower Motor |
Table 2: | Auxiliary Blower Resistor |
Table 3: | Auxiliary Blower Motor Relay, Low |
Table 4: | Auxiliary Blower Motor Relay, Medium |
Table 5: | Auxiliary Blower Motor Relay, High |
Table 6: | Auxiliary Heater Control Switch |
Table 7: | Blower Motor, Connector C1 |
Table 8: | Blower Motor, Connector C2 |
Table 9: | Blower Motor Relay, High |
Table 10: | Blower Resistor |
Table 11: | HVAC Control Module Connector C2 (Blower Switch) |
| |||||||
---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
A | YEL | 1172 | Auxiliary Blower Motor Feed | ||||
B | BLK | 150 | Ground |
| |||||||
---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
A | LT BLU | 1072 | Auxiliary Blower Resistor Output - Medium | ||||
B | WHT | 1152 | Auxiliary Blower Motor Feed | ||||
C | YEL | 1151 | Auxiliary Blower Motor Output - Low |
| |||||||
---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
1 | RED | 542 | Fuse Output - Battery - Type I Fuse | ||||
2 | DK BLU | 1926 | Ground | ||||
3 | -- | -- | Not Used | ||||
4 | YEL | 1176 | Auxiliary Blower Motor Resistor Output - Low | ||||
5 | BRN | 341 | Fuse Output - Ignition 3 Type III Fuse |
| |||||||
---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
1 | RED | 542 | Fuse Output - Battery - Type I Fuse | ||||
2 | RED | 1925 | Ground | ||||
3 | -- | -- | Not Used | ||||
4 | LT BLU | 1072 | Auxiliary Blower Motor Resistor Output - Med | ||||
5 | BRN | 341 | Fuse Output - Ignition 3 Type III Fuse |
| |||||||
---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
1 | RED | 542 | Fuse Output - Battery - Type I Fuse | ||||
2 | WHT | 1925 | Ground | ||||
3 | -- | -- | Not Used | ||||
4 | YEL | 1152 | Auxiliary Blower Motor Output - High | ||||
5 | BRN | 341 | Fuse Output - Ignition 3 Type III Fuse |
| |||||||
---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
A | GRY | 8 | IP Lamp Feed | ||||
B | BLK | 150 | Ground | ||||
C | -- | -- | Not Used | ||||
D | WHT | 1924 | Auxiliary HVAC Switch Output - High | ||||
E | DK BLU | 1926 | Auxiliary HVAC Switch Output - Low | ||||
F | RED | 1925 | Auxiliary HVAC Switch Output - Medium |
| |||||||
---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
A | PPL | 65 | Power Motor Feed |
| |||||||
---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
A | BLK | 150 | Ground |
| |||||||
---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
A1 | BLK | 150 | Ground | ||||
A2 | RED | 542 | Fuse Output Battery - Type II Fuse | ||||
B1 | -- | -- | Not Used | ||||
B2 | DK BLU | 101 | Blower Resistor Output | ||||
C1 | PPL | 65 | Blower Motor Feed | ||||
C2 | ORN | 52 | Blower Switch Output - High |
| |||||||
---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
A | YEL | 60 | Blower Switch Output - Low | ||||
B | DK BLU | 101 | Blower Resistor Output | ||||
C | TAN | 63 | Blower Switch Output - Medium 1 | ||||
D | LT BLU | 72 | Blower Switch Output - Medium 2 |
| |||||||
---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
A | LT BLU | 72 | Blower Switch Output - Medium 2 | ||||
B | TAN | 63 | Blower Switch Output - Medium 1 | ||||
C | YEL | 60 | Blower Switch Output - Low | ||||
D | DK GRN | 71 | A/C Selector Switch Output | ||||
E-F | -- | -- | Not Used | ||||
G | BRN | 141 | Fuse Output - Ignition 3 Type III Fuse | ||||
H | ORN | 52 | Blower Switch Output - High |