Catalytic Converter Replacement Gas, Below8600 lb (GVWR)
Removal Procedure
- Raise and suitably support the vehicle. Refer to
Lifting and Jacking the Vehicle
in General Information.
- Disconnect the oxygen
sensor electrical connections.
- Remove the nuts from the
Y-pipe flat flange.
- Remove the nuts, the studs
and the flange seals from the Y-pipe and the exhaust manifold.
- Remove the Y-pipe and the catalytic converter assembly.
Installation Procedure
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the new
flange seals to the connecting the Y-pipe, catalytic converter assembly
at the exhaust manifold.
- Install the studs into the exhaust manifold.
Tighten
Tighten the studs to 22 N·m (16 lb ft).
- Install the nuts to the studs in the exhaust manifold.
Tighten
Tighten the nuts to 64 N·m (47 lb ft).
- Position the Y-pipe and
the catalytic converter assembly to the flat flange.
- Install the nuts to the
flat flange studs.
Tighten
Tighten the nuts to 64 N·m (47 lb ft).
- Connect the oxygen sensor
electrical connections.
- Check for clearance and alignment.
- Lower the vehicle.
Catalytic Converter Replacement Diesel
Removal Procedure
- Raise and suitably support the vehicle. Refer to
Lifting and Jacking the Vehicle
in General Information.
- Remove the front exhaust
pipe flange stud nuts from the front of the catalytic converter assembly.
Remove the clamp from the exhaust manifold pipe.
- Remove the U-bolt from
the rear of the catalytic converter assembly.
- Remove the catalytic converter
from the muffler assembly.
Installation Procedure
- Install a new flange gasket
and the catalytic converter to the front exhaust pipe flange studs.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the nuts
to the exhaust pipe flange studs.
Tighten
Tighten the stud nuts to 64 N·m (47 lb ft).
- Install a new U-bolt to
the rear of the catalytic converter.
Tighten
Tighten the U-bolt to 42 N·m (31 lb ft).
- Install the clamp to the exhaust manifold pipe.
Tighten
Tighten the clamp nuts to 12 N·m ( 106 lb in).
- Check for clearance and alignment.
- Lower the vehicle.
Catalytic Converter Replacement Gas, Export
Removal Procedure
- Raise and suitably support the vehicle. Refer to
Lifting and Jacking the Vehicle
in General Information.
- Remove the nuts from the
Y-pipe flat flange.
- Remove the muffler and the catalytic converter assembly.
- Remove the nuts, studs,
and flange seals from the Y-pipe and the exhaust manifold.
Installation Procedure
- Install the new flange
seals.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the new
studs.
Tighten
Tighten the studs to 22 N·m (16 lb ft).
- Install the new nuts connecting the Y-pipe, catalytic converter
assembly to the exhaust manifold.
Tighten
Tighten the nuts to 64 N·m (47 lb ft).
- Position the Y-pipe and
the catalytic converter assembly to the flat flange.
- Install the nuts to the flat flange studs.
Tighten
Tighten the nuts to 64 N·m (47 lb ft).
- Check for clearance and alignment.
- Lower the vehicle.
Catalytic Converter Replacement Gas, 8600 lb and Above
Removal Procedure
- Raise and suitably support the vehicle. Refer to
Lifting and Jacking the Vehicle
.
- Disconnect the oxygen
sensor electrical connections.
- Remove the nuts from the
Y-pipe flat flange.
- Remove the nuts, studs
and flange seals from the Y-pipe and the exhaust manifold.
- Remove the Y-pipe and
the catalytic converter assembly.
- Remove the muffler and the catalytic converter assembly.
Installation Procedure
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the flange
seals to the Y-pipe, catalytic converter assembly at the exhaust manifold.
- Install the studs into the exhaust manifold.
Tighten
Tighten the studs to 22 N·m (16 lb ft).
- Install the exhaust nuts to the studs in the exhaust manifold.
Tighten
Tighten the nuts to 64 N·m (47 lb ft).
- Install the muffler and the catalytic converter assembly.
- Position the Y-pipe and
the catalytic converter assembly to the flat flange.
- Install the nuts to the flat flange studs.
Tighten
Tighten the nuts to 64 N·m (47 lb ft).
- Connect the oxygen sensor
electrical connections.
- Check for clearance and alignment.
- Lower the vehicle.