Removal Procedure
Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing
any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to
the vehicle or its components.
- Disconnect
the battery negative cable.
- Disconnect the terminal plug from the back of the generator.
- Disconnect the battery lead from the back of the generator.
- Remove the upper fan shroud if necessary. Refer to
Fan Shroud Replacement
in Engine Cooling.
- Remove the drive belt from the generator. Refer to
Drive Belt Replacement
, in Engine Mechanical (5.0L
and 5.7L),
Drive Belt Replacement
, in Engine Mechanical (6.5L), or
Drive Belt Replacement
, in Engine Mechanical
(7.0L and 7.4L).
- Remove the auxiliary brace bolts. Refer to
Generator Brace Replacement - Auxiliary
.
- Remove the remaining generator bracket bolts.
- Lift the hose from the
generator support.
- Remove the generator.
Installation Procedure
- Install the generator.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the generator
bracket bolts.
Tighten
Tighten the generator mounting bolts to 50 N·m (37 lb ft).
- Install the auxiliary brace bolts. Refer to
Generator Brace Replacement - Auxiliary
.
- Place the hose on the generator support.
- Install the drive belt to the generator. Refer to
Drive Belt Replacement
, in Engine Mechanical (5.0L
and 5.7L),
Drive Belt Replacement
, in Engine Mechanical (6.5L), or
Drive Belt Replacement
, in Engine Mechanical
(7.0L and 7.4L).
- Install the upper fan shroud if necessary. Refer to
Fan Shroud Replacement
in Engine Cooling.
- Connect the battery lead to the back of the generator.
Tighten
Tighten the battery terminal nut to 8 N·m (71 lb in).
- Connect the terminal plug from the back of the generator.
- Connect the battery negative cable.