Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: This test should be performed when the Defogger does not operate properly. | ||||
1 | Has the Defogger System Check been performed? | -- | Go to Defogger System Check | |
2 |
Does the test lamp light? | -- | ||
3 | Repeat Step 2. Does the test lamp remain lit? | -- | ||
4 |
Does the test lamp light? | -- | ||
5 | Refer to Defogger Grid Lines Diagnosis . Is the Repair Complete? | -- | Go to Defogger System Check | -- |
6 | Repair the open in CKT 293 (PPL) between the Rear Window Defogger Grid and connector C222 at the Convenience Center. Is the repair complete? | -- | Go to Defogger System Check | -- |
7 |
Does the test lamp light? | -- | ||
8 | Connect a tst light between terminal A and D of Connector C1. Does the test lamp light? | -- | ||
9 | Repair the open in CKT 1440 (ORN) between the HVAC Control Module and the Underhood Fuse Block. Is the repair complete? | -- | Go to Defogger System Check | -- |
10 | Replace the HVAC Control Module. Is the repair complete? | -- | Go to Defogger System Check | -- |
11 | Repair the open in CKT 293 (PPL) between the HVAC Control Module and the Convvenience Center. Is the repair complete? | -- | Go to Defogger System Check | -- |