Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Has the Power Door Locks System Check been performed? | -- | Go to Step 2 | |
2 |
Does the test lamp light? | -- | Go to Step 3 | Go to Step 4 |
3 |
Do the doors lock and then unlock? | -- | Go to Step 5 | Go to Step 6 |
4 | Repair the open in CKT 640 (ORN) between the inoperative power door lock switch and splice S256. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
5 | Replace the door lock switch. Refer to Power Accessory Switch Panel Replacement . Is the repair complete? | -- | -- | |
6 |
Is the repair complete? | -- | -- |