• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Liftgate Module B+ | B396A 02, B153A 08 | B396A 02, B153A 08 | -- | -- |
Liftgate Position Sensor 5V Reference Voltage | 2 | B153E 08 | 2 | -- |
Full Open Signal | B153B 02 | 2 | 2 | -- |
Liftgate Disable Signal | 1, 2 | 1 | 1 | -- |
Liftgate Open Signal | 1 | 1 | 1 | -- |
Object Sensors Signal | B153F 02 | B153F 05 | B153F 05 | B153F 03, B153F 07 |
Open/Close Switches Signal | B2494 02 | 1, 2 | 1, 2 | -- |
Pawl Switch Signal | B153A 00 | B153A 00 | B153A 00 | B153A 08 |
Position Sensor Signal 1 | B153E 02 | B153E 05, B153E 08 | B153E 05 | -- |
Position Sensor Signal 2 | B153E 02 | B153E 05, B153E 08 | B153E 05 | -- |
Ratchet Switch Signal | B153A 00 | B153A 00 | B153A 00 | B153A 08 |
Sector Switch Signal | B153A 00 | B153A 00 | B153A 00 | B153A 08 |
Disengage Clutch Control | B396B 02 | B396B 04 | B396B 01 | -- |
Engage Clutch Control | B396B 02 | B396B 04 | B396B 01 | -- |
Liftgate Latch Cinch Control | B2495 02 | B2495 04 | B2495 01 | -- |
Liftgate Latch Release Control | B2495 02 | B2495 04 | B2495 01 | -- |
Liftgate Motor Close Control | B396A 02 | B396A 04 | B396A 01 | -- |
Liftgate Motor Open Control | B396A 02 | B396A 04 | B396A 01 | -- |
Full Open Low Reference | -- | 2 | 2 | -- |
Liftgate Switches Low Reference | -- | 1 | 1 | -- |
Position Sensor Low Reference | -- | B0153E 08 | 2 | -- |
I/P Switch Ground | -- | 1 | 1 | -- |
Liftgate Control Module Ground | -- | 2 | 2 | -- |
1. Liftgate Switch Malfunction 2. Liftgate Malfunction |
The full open switch is part of the gear motor assembly and will close and become active when the liftgate reaches the full open position. The full open switch signal circuit is supplied battery voltage through a resistor and monitored within the liftgate control module. The liftgate control module (LGM) provides a low reference circuit and when the switch contacts close, the signal circuit goes low and the LGM determines the switch to be active.
• | System voltage to the liftgate control module must be 9-16 volts. |
• | Power open or close operation is attempted. |
The LGM detects a short to ground in the full open switch signal circuit
The LGM detects an open/high resistance in the full open switch signal circuit.
The power liftgate will not power close.
• | The DTC will be current for as long as the fault is present. |
• | When the fault is no longer present, the DTC will be a history DTC. |
• | A history DTC will clear after 50 ignition cycles. |
Vehicle Access Connector End Views
Rear Hatch/Gate Description and Operation
Ignition ON, observe the scan tool LGM Full Open Switch while opening and closing the liftgate. The parameter should change between Active and Inactive.
⇒ | If not the specified value, replace the LGM. |
⇒ | If greater than the specified range, replace the liftgate motor assembly. |
⇒ | If less than the specified value, replace the liftgate motor assembly. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for liftgate control module replacement, programming and setup |