GM Service Manual Online
For 1990-2009 cars only

Object Number: 1971846  Size: MF

Callout

Component Name

Danger: Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.

The High Voltage Disabling procedure will perform the following tasks:

   • Identify how to disable high voltage.
   • Identify how to test for the presence of high voltage.
   • Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed.
Failure to follow the procedures exactly as written may result in serious injury or death.

Preliminary Procedures

  1. Disable the high voltage at the drive motor generator battery. Refer to High Voltage Disabling.
  2. Remove the upper, front, and right side covers. Refer to Drive Motor Battery Case Upper Cover, Front Cover, and Right Side Cover Replacement.

1

Wiring Harness Connector (Qty: 4)

2

Drive Motor Battery Positive Relay Nuts (Qty: 2)

Caution: Refer to Fastener Caution in the Preface section.

Tighten
3 N·m (27 lb in)

3

Drive Motor Battery Inverter Current Limit Relay

Procedure

After the relay has been replaced and the re-assembly of the drive motor generator battery, enable the HV system. Refer to High Voltage Enabling.