Special Tools
J 45059
Angle Meter
Removal Procedure
- Remove the camshaft position (CMP) actuator magnet. Refer to
Camshaft Position Actuator Magnet Replacement
.
- Remove and discard the CMP actuator solenoid valve.
Installation Procedure
- Install the a NEW CMP actuator solenoid valve until snug.
With the CMP actuator properly positioned
onto the camshaft, the CMP actuator solenoid valve can be threaded completely into the camshaft using light hand pressure. Tighten by hand until snug.
Notice: Refer to Fastener Notice in the Preface section.
- Tighten the CMP actuator solenoid valve.
Tighten
- Tighten the solenoid valve a first pass to 65 N·m (48 lb ft).
- Tighten the solenoid valve a final pass and additional 90 degrees using
J 45059
.
- Install the CMP actuator magnet. Refer to
Camshaft Position Actuator Magnet Replacement
.