Refer to the below data tables when one of the following conditions exist:
• | The RTD Diagnostic System Check is complete. |
• | The on board diagnostics are operating correctly. |
• | No diagnostic trouble codes (DTCs) are displayed. |
The typical scan tool data values are an average of the displayed values recorded from normally operating vehicles. The typical scan tool data values are intended to represent what a normally functioning system would display with certain preliminary settings. The values you get may vary slightly due to a low battery charge or other reasons. But the values should be very close.
Use only the parameters listed in the tables for diagnosis. If a scan tool reads other parameters, the values are not recommended for use in diagnosis. Refer to the Scan tool data definitions for further detailed information.
Preliminary Settings: The following preliminary settings must be set in order to achieve the same typical data values listed in the table.
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Park brake set with the ignition switch ON / Ignition Switch in RUN / Engine running / Automatic Transmission in PARK / Air Conditioning is OFF | |||
RTD Module ID | Data | -- | varies with the vehicle |
Battery Voltage | Data | Volts | 12.0 - 14.7 Volts (varies with the vehicle) |
Ignition 3 Voltage | Data | Volts | 12.0 - 14.7 Volts (varies with the vehicle) |
Steering Position Sensor 1 | Data | Volts | 0.35 to 4.7 |
Steering Position Sensor 2 | Data | Volts | 0.35 to 4.7 |
EVO Actuator Desired @ 0 MPH | Data | ma | 0 |
EVO Actuator Actual @ 0MPH | Data | ma | 0 |
EVO Actuator Desired @ 65 MPH | Data | ma | 625 mA |
EVO Actuator Actual @ 65 MPH | Data | ma | 625 mA |
Vehicle Speed | Data | MPH | 0 |
Exhaust Signal | Data | ON/OFF | OFF |
RTD Solenoid LF | Data | ON/OFF | OFF |
RTD Solenoid LR | Data | ON/OFF | OFF |
Compress Relay Enable | Data | ON/OFF | OFF |
RTD Solenoid RF | Data | ON/OFF | OFF |
RTD Solenoid RR | Data | ON/OFF | OFF |
RTD Position Sensor LF | Data | Volts | 0.5 to 4.85 |
RTD Position Sensor RF | Data | Volts | 0.5 to 4.85 |
RTD Position Sensor LR | Data | Volts | 0.5 to 4.85 |
RTD Position Sensor RR | Data | Volts | 0.5 to 4.85 |
RTD Air Pressure Sensor | Data | Volts | 0.15 to 4.85 |
Sensor Supply Voltage | Data | Volts | 4.8 to 5.2 |
(RTD) SERVICE RIDE CONTROL message | Outputs | ON/OFF | OFF |