GM Service Manual Online
For 1990-2009 cars only

Application

Specification

Metric

English

Accumulator Bracket Mounting Nut

9 N·m

80 lb in

Air Inlet Actuator Mounting Screw

1.6 N·m

14 lb in

Air Outlet Mounting Screw

1.6 N·m

14 lb in

Blower Motor Relay/Resistor Screws

1.6 N·m

14 lb in

Blower Motor Insulating Cover

1.6 N·m

14 lb in

Compressor Bracket Mounting Bolt

50 N·m

37 lb ft

Compressor Mounting Bolt

50 N·m

37 lb ft

Condenser Mounting Bolts

9 N·m

80 lb in

Evaporator Pipe to Accumulator Nut

16 N·m

12 lb ft

Evaporator Pipe to Condenser Nut

16 N·m

12 lb ft

Evaporator Tube to Evaporator

28 N·m

21 lb ft

Extended Console Mounting Screw

1.6 N·m

14 lb in

Floor Air Outlet Screws

1.6 N·m

80 lb in

Heater Core Cover Screws

9 N·m

14 lb in

Heater Hose Mounting Bolt

25 N·m

18 lb ft

Hose to Accumulator Nut

16 N·m

12 lb ft

Hose to Condenser Nut

16 N·m

12 lb ft

HVAC Module Mounting Nuts

4 N·m

35 lb in

HVAC Module Mounting Screws

4 N·m

35 lb in

HVAC Module Screws

1.6 N·m

14 lb in

Mode Actuator Mounting Screw

1.6 N·m

14 lb in

Negative Battery Cable Bolt

17 N·m

13 lb ft

Passenger Compartment Air Filter Access Door Screw

1.6 N·m

14 lb in

Pressure Cycling Switch

4 N·m

35 lb in

Refrigerant Hose to Compressor Bolt

34 N·m

25 lb ft

Temperature Actuator Mounting Screw

1.6 N·m

14 lb in

System Performance

Control Settings

System Response

Mode Control

Temp Control

Fan Switch

Blower Speed

Heater Outlets

A/C Outlets

Defroster Outlets

See Remarks

--

Cold

--

Off

No Air Flow

No Air Flow

No Air Flow

--

Upper

Cold

Lo

Low

No Air Flow

Air Flow

No Air Flow

A,C,D

Upper

Cold

Low to Hi

Low to High

No Air Flow

Air Flow

No Air Flow

A,B,C,D

Upper

Cold

Hi

High

No Air Flow

Air Flow

No Air Flow

A,D

Bi-Level

Cold

Hi

High

Air Flow

Air Flow

No Air Flow

A,D

Lower

Hot

Hi

High

Air Flow

No Air Flow

Min Air Flow

A,D

Defog

Hot

Hi

High

Air Flow

No Air Flow

Air Flow

A,D

Defrost

Hot

Hi

High

Min Air Flow

No Air Flow

Air Flow

A,D

  • A = Engagement of the detent must be felt in each mode.
  • B = Noticeable blower speed increase must occur from low to Med 1, Med 2, Med 3, and high.
  • C = Listen for changes of air noise from recirculation door closing.
  • D = Some air bleed will occur through defroster and side window defogger vents in heater mode.