The numbers below refer to thew step numbers on the diagnostic table.
This step ensures that the primary HVAC system is functioning properly.
The DTC's listed could set if a calibration of the actuators is performed.
If the condition does not occur when a heating request has been made then you must bypass the A/C compressor and cooling system diagnostic information.
This step ensures that the rear auxiliary HVAC control module is able to move the auxiliary air temperature actuator.
This step ensures that the front auxiliary HVAC control assembly is able to move the auxiliary air temperature actuator.
The infrared sensor is located between the auxiliary blower motor switch and the auxiliary temperature switch on rear auxiliary HVAC control module. It has a glass cover protecting the sensor which is integral to the rear auxiliary HVAC control module.
Step | Action | Values | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: Auxiliary air temperature can not be adjusted from one or both auxiliary controls or auxiliary heating is insufficient. | ||||||||||||||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |||||||||||||
Important:: The auxiliary HVAC control assembly operates independently of the HVAC control module to provide heated airflow through the auxiliary system. Does the HVAC control module operate and provide sufficient heating? | -- | Go to Step 3 | Go to Too Cold in Vehicle | |||||||||||||
Important:: If during this diagnostic procedure the HVAC control module is disconnected a recalibration of actuators must be performed to avoid misdiagnosis.
Does the scan tool display DTC B0229, B0414, B0434, B3761 or B3764? | -- | Go to Step 4 | ||||||||||||||
4 |
Does the auxiliary blower motor operate at all? | -- | Go to Step 5 | |||||||||||||
5 | Does the auxiliary blower motor operate at the desired speed for each speed position? | -- | Go to Step 6 | |||||||||||||
Does the Auxiliary Too Cold in Vehicle concern occur when heating is required? | -- | Go to Step 7 | Go to Step 9 | |||||||||||||
7 |
Does the A/C compressor operate? | -- | Go to Step 8 | |||||||||||||
8 | Inspect the cooling system for the following:
Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 9 | ||||||||||||
Do the counts change? | -- | Go to Step 10 | Go to Step 13 | |||||||||||||
Do the counts change? | -- | Go to Step 11 | Go to Step 15 | |||||||||||||
Place your hand directly over the infrared sensor on the rear auxiliary HVAC control module. Does the temperature value change? | -- | Go to Step 12 | Go to Step 21 | |||||||||||||
12 |
Does the resistance measure near the sensor resistance table value? | -- | Go to Step 17 | |||||||||||||
13 | Test the 5 volt reference circuit of the front auxiliary HVAC control assembly for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 14 | ||||||||||||
14 | Test the front auxiliary temperature door control circuit of the front auxiliary HVAC control assembly for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 16 | ||||||||||||
15 | Test the front auxiliary temperature door control circuit of the front auxiliary HVAC control assembly for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 16 | ||||||||||||
16 |
Does the resistance change? | -- | Go to Step 20 | Go to Step 19 | ||||||||||||
17 | Check the suspect air temperature sensor for proper installation. Refer to Air Temperature Sensor Replacement - Upper Auxiliary or Air Temperature Sensor Replacement - Lower Auxiliary . Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 18 | ||||||||||||
18 | Inspect for poor connections at the harness connector of the suspect air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 21 | ||||||||||||
19 | Inspect for poor connections at the harness connector of the front auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 22 | ||||||||||||
20 | Inspect for poor connections at the harness connector of the auxiliary HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 23 | ||||||||||||
21 | Replace the suspect air temperature sensor. Refer to Air Temperature Sensor Replacement - Upper Auxiliary or Air Temperature Sensor Replacement - Lower Auxiliary . Did you complete the replacement? | -- | Go to Step 24 | -- | ||||||||||||
22 | Replace the front auxiliary HVAC control assembly. Refer to Auxiliary Heater and Air Conditioning Control Replacement - Front . Did you complete the replacement? | -- | Go to Step 24 | -- | ||||||||||||
23 | Replace the auxiliary HVAC control module. Refer to Auxiliary Heater and Air Conditioning Control Module Replacement . Did you complete the replacement? | -- | Go to Step 24 | -- | ||||||||||||
24 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |
The numbers below refer to thew step numbers on the diagnostic table.
This step ensures that the primary HVAC system is functioning properly.
If the condition does not occur when a heating request has been made then you must bypass the A/C compressor and cooling system diagnostic information.
Step | Action | Values | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: Auxiliary air temperature cannot be adjusted from one or both auxiliary controls or auxiliary heating is insufficient. | ||||||||||||||||
1 | Did you review the HVAC operation and perform the necessary inspections? | -- | Go to Step 2 | |||||||||||||
Important:: The auxiliary HVAC control assembly operates independently of the HVAC control module to provide heated airflow through the auxiliary system. Does the HVAC control module operate and provide sufficient heating? | -- | Go to Step 3 | Go to Too Cold in Vehicle | |||||||||||||
3 |
Does the auxiliary blower motor operate at all? | -- | Go to Step 4 | |||||||||||||
4 | Does the auxiliary blower motor operate correctly for each speed position? | -- | Go to Step 5 | |||||||||||||
Inspect the cooling system for the following conditions:
Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 6 | |||||||||||||
6 |
Does the A/C compressor operate? | -- | Go to Step 7 | |||||||||||||
7 |
Does the auxiliary air temperature actuator drive shaft rotate at all? | -- | Go to Step 8 | Go to Step 9 | ||||||||||||
8 | Inspect the auxiliary air temperature door and the auxiliary air temperature actuator for the following conditions:
Did you find and correct the condition? | -- | Go to Step 18 | |||||||||||||
9 | Test the ignition 3 voltage circuit of the auxiliary air temperature actuator for an open or a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 10 | ||||||||||||
10 | Test the ground circuit of the auxiliary air temperature actuator for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 11 | ||||||||||||
11 | Test the temperature door control circuit of the auxiliary air temperature actuator for an open, a high resistance, short to ground or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 12 | ||||||||||||
12 |
Important:: The auxiliary HVAC control assembly connector must be connected to correctly perform test.
Does the voltage change and measure within the specified range? | 0-12 V | Go to Step 13 | Go to Step 15 | ||||||||||||
13 | Inspect for poor connections at the harness connector of the auxiliary air temperature actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 14 | ||||||||||||
14 | Inspect the auxiliary air temperature actuator, door and any attaching linkage for binding or a condition that prevents drive shaft rotation Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 16 | ||||||||||||
15 | Inspect for poor connections at the harness connector of the auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 17 | ||||||||||||
16 | Replace the auxiliary air temperature actuator. Refer to Auxiliary Temperature Valve Actuator Replacement . Did you complete the replacement? | -- | Go to Step 18 | -- | ||||||||||||
17 | Replace the auxiliary HVAC control assembly. Refer to Auxiliary Heater and Air Conditioning Control Replacement - Front . Did you complete the replacement? | -- | Go to Step 18 | -- | ||||||||||||
18 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |