This step verifies that the HVAC control module Fan Up Switch parameter matches the requested state of the blower motor switch.
This step verifies that the HVAC control module Fan Down Switch parameter matches the requested state of the blower motor switch.
Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor operates in at least one speed position. | ||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information |
Does the scan tool indicate that the Fan Up Button parameter changes state? | -- | Go to Step 3 | Go to Step 10 | |
Does the scan tool indicate that the Fan Down Button parameter changes state? | -- | Go to Step 4 | Go to Step 10 | |
4 | Place the blower motor switch in each speed position. Does the blower motor operate at the desired speeds? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 5 |
5 |
Does the voltage measure within the specified range? | 10-14 V | Go to Step 6 | Go to Step 8 |
6 |
Does the voltage measure within the specified range? | 4.5-5.5 V | Go to Step 9 | Go to Step 7 |
7 | Test the control circuit of the blower motor control processor for a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 9 |
8 | Test the battery positive voltage circuit of the blower motor control processor for a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 11 |
9 | Inspect for poor connections at the harness connector of the blower motor control processor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 12 |
10 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 13 |
11 | Repair a high resistance in the ground circuit of the blower motor control processor. Refer to Circuit Testing in Wiring Systems. Did you complete the repair? | -- | Go to Step 14 | -- |
12 | Replace the blower motor control processor. Refer to Blower Motor Control Processor Replacement . Did you complete the replacement? | -- | Go to Step 14 | -- |
13 | Replace the HVAC control module. Refer to Control Module References in Computer/Integrating Systems for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 14 | -- |
14 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |