• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Control | P0ADB | P0ADC | P0ADC | -- |
Ground | -- | P0ADC | -- | -- |
The hybrid drive motor generator battery contains 3 high voltage (HV) contactor relays. The contactor relays allow the high voltage DC batteries to be connected to the vehicle or safely contain the DC high voltage within the drive motor generator battery assembly. The three contactor relays are a positive HV contactor relay, negative HV contactor relay, and current limit relay. These relays/contactors close and open in a certain sequence and are controlled by the BECM. The control circuit for the contactor relays use a wire from the relay to case ground and the BECM supplies voltage to turn them on and off individually. The BECM monitors the control circuit voltage to these relays and 12 V reference circuit internal to the control module to determine if the circuit is open by comparing the two voltage readings. If the BECM detects 2 failed high-voltage precharge events, a 20-40 minute precharge wait time is activated by the BECM. This precharge wait time limit is to allow the precharge circuit internal to the drive motor generator battery assembly to cool down. The precharge wait time counts down in seconds and is displayed on the scan tool.
• | The ignition is ON. |
• | The jump assist function is not active. |
• | The 12 V battery voltage is 9-18 V. |
• | HV contactor relays are commanded closed. |
• | The 12 V battery voltage is 9-18 V. |
• | HV contactor relays are commanded open. |
The BECM compares the contactor control circuit to the BECMs internal 12 V measurement reference circuit. This DTC sets when the contactor control circuit voltage is 2 V less than the BECMs internal voltage reference when the HV contactor relay is commanded closed.
The BECM compares the contactor control circuit to the BECMs internal 12 V measurement reference circuit. This DTC sets when the contactor control circuit voltage and the BECMs internal voltage reference are within 2 V of each other when the HV contactor relay is commanded open.
DTCs P0ADB and P0ADC are type C DTCs.
DTCs P0ADB and P0ADC are type C DTCs.
Hybrid Energy Storage Schematics
Drive Motor Battery System Description
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
EL-48900 HEV Safety Kit
Danger: Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.
The High Voltage Disabling procedure will perform the following tasks:• | Identify how to disable high voltage. |
• | Identify how to test for the presence of high voltage. |
• | Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BECM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the BECM. |
Danger: Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.
The High Voltage Disabling procedure will perform the following tasks:• | Identify how to disable high voltage. |
• | Identify how to test for the presence of high voltage. |
• | Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed. |
⇒ | If not within the specified range, replace the contactor relay. |
Perform the Diagnostic Repair Verification after completing the repair.
• | Control Module References - for drive motor generator battery control module replacement, setup and programming. |