Table 1: | Blunt Cut Wire Set |
Table 2: | Shielded Wire Set |
CKT 2240 (ORN) receives voltage at all times from the SEO1 fuse. CKT 243 (YEL) receives voltage with the ignition switch in the run and accessory position from the SEO ACCY fuse. Ground is supplied through CKT 1850 (BLK) from splice pack 203 and G203.
CKT # | Color | Description | Comments |
---|---|---|---|
243 | Yellow | Accessory Power Feed | 10A Fuse, 7.0A Capacity |
835 | DK Green | Radio Serial Communication | Entertainment & Communication Bus, 1KB |
2240 | Orange | Battery Feed | 15A Fuse, 10.5A Capacity |
1850 | Black | Ground | 15A Capacity |
CKT # | Color | Description |
---|---|---|
654 | Bare Conductor | Microphone Ground & Shield Return |
655 | Gray | Microphone Signal |