• | J 25070 Heat Gun - Capable of 260°C (500°F) or equivalent |
• | Test Lamp |
• | Rear Window Defogger Repair Kit GM P/N 12346001, Canada P/N 10951643 or equivalent |
Caution: To avoid personal injury:
• Do not allow the repair material to come in contact with skin
or eyes and avoid breathing vapors. • Do not use near sparks or open flame.
Important:
• Ensure that the grid line repair material is not beyond the expiration
date. • Repair decal or tape must be used in order to control the width of the
repair area. • If the repair decal is used, verify that the die-cut metering slot is
the same width as the grid line. • Thoroughly stir the grid line repair material until a uniform color
appears. • Verify that there are no air bubbles in the grid line repair material
in the repair area.
Apply the grid line repair (2) decal or 2 strips of the tape above and below the repair area.
Notice: The grid line repair material must be cured with heat. To avoid heat damage to the interior trim, protect the trim near the repair area where heat is to be applied.
Important: Use J 25070 capable of 260°C (500°F) or equivalent . If you do not use a heat gun, allow at least 24 hours at an ambient temperature of 21-32°C (70-90°F) for complete curing of the repair materials. Do NOT physically disturb the repair area until after that time.
The grid line will be electrically operative immediately after the repair.• | Hold the heat gun nozzle 25 mm (1 in) from the surface. |
• | Heat the repair area for 2-3 minutes. |