Notice: Ensure the intake manifold does not shift as the intake manifold bolts are tightened in the proper sequence. Failure to follow the entire intake manifold bolt tightening sequence exactly, may result in an oil leak and serious engine damage.
Important:
• The entire intake manifold tightening sequence must be promptly completed prior to the curing of the bolt threadlocking and intake manifold sealing materials. Failure to do so may result in false torque readings and ineffective bolt threadlocking. • DO NOT reuse the intake manifold bolts during assembly.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Important: Lubricate the injector O-ring seals with clean engine oil and install onto the spray tip end of each injector.
Tighten
Tighten the fuel injection fuel rail studs and/or bolts to 12 N·m (106 lb in).