When you first turn the ignition switch to the RUN position, the inflatable restraint Sensing and Diagnostic Module (SDM) performs tests to diagnose critical malfunctions within itself. Next the SDM measures IGNITION 1, 23 VLR and the deployment loop voltages to make sure they are within their respective normal voltage ranges. Then the SDM proceeds to CONTINUOUS MONITORING. The SDM contains a resistor network connected to 5 volts, ground, and to the SDM front end discriminating sensor signal terminal 9. The 1.0 K ohm resistor in the inflatable restraint front end discriminating sensor parallel to the normally open switch provides a parallel path to ground. This causes a specified percentage of voltage to appear at the SDM front end discriminating sensor signal input. The SDM monitors this voltage to detect shorts to power or an open discriminating sensor.
• | The SDM is configured for an inflatable restraint front end discriminating sensor |
• | The voltage at front end discriminating sensor signal terminal 9 is more than 5.0 volts for 500 milliseconds. |
The CONTINUOUS MONITORING test checks for this DTC. This test occurs when IGNITION 1 is within the normal operating voltage range.
• | The SDM sets a Diagnostic Trouble Code. |
• | The SDM turns ON the AIR BAG warning lamp. |
• | Current DTC-The voltage at front end discriminating sensor signal terminal 9 is less than 3.2 volts for 500 milliseconds. |
• | History DTC |
- | You issue a scan tool CLEAR CODES command. |
- | Once 250 malfunction free ignition cycles have occurred. |
A broken or chafed wire in the inflatable restraint front end discriminating sensor circuit can cause an intermittent condition. Inspect CKT 1834 and CKT 1751 carefully for cutting or chafing.
When measurements are requested in this table, use the J 39200 DMM with the correct terminal adapter from the J 35616 Connector Test Adapter Kit. When an inspection for proper connection is requested, refer to Testing for Electrical Intermittents in Wiring Systems. When a wire, connector or terminal repair is requested, use the J-38125 Terminal Repair Kit and refer to Wiring Repairs in Wiring Systems.
The numbers below refer to the step numbers on the diagnostic table:
This test checks for proper contact or corrosion of the yellow 2-way connector.
This test checks for a malfunctioning discriminating sensor.
This test checks for an open in CKT 1751.
This test isolates the open in CKT 1751 to one side of C110.
This test checks for proper contact or corrosion of the inflatable restraint Sensing and Diagnostic Module (SDM) connector.
This test checks for an open in CKT 1834.
This test isolates the open in CKT 1834 to one side of C110.
This test checks for a short to voltage in CKT 1834.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the SIR Diagnostic System Check performed? | -- | ||
Are the terminals damaged or corroded? | -- | |||
3 | Replace the sensor harness connector. Refer to Wiring Repair . Are the repairs complete? | -- | -- | |
4 | Check for proper connection at the sensor connector terminals A and B. Are the terminals damaged or corroded? | -- | ||
5 | Check for proper connection at the sensor connector terminals A and B. Are the terminals damaged or corroded? | -- | ||
6 | Replace the inflatable restraint front end discriminating sensor. Refer to Inflatable Restraint Front End Discriminating Sensor Replacement . Are the repairs complete? | -- | -- | |
Is the resistance reading more than the specified value? | 1050 ohms | |||
Measure the resistance from the sensor harness connector terminal B to ground. Is the resistance reading within the specified values? | 0-5 ohms | |||
9 |
Is the terminal damaged or corroded? | -- | ||
10 | Replace C110. Are the repairs complete? | -- | -- | |
Is the resistance reading within the specified values? | 0-5 ohms | |||
12 | Repair an open condition in CKT 1751 between C110 and G201. Are the repairs complete? | -- | -- | |
13 | Repair an open condition in CKT 1751 between C110 and the inflatable restraint front end discriminator sensor harness connector. Are the repairs complete? | -- | -- | |
Is the connector damaged or corroded? | -- | |||
15 | Replace the SDM harness connector. Refer to Wiring Repair . Are the repairs complete? | -- | -- | |
16 | Check for proper connection at terminal 9 of the SDM. Is the terminal damaged or corroded? | -- | ||
17 | Check for proper connection at terminal 9 of the SDM. Is the terminal damaged or corroded? | -- | ||
18 | Replace the SDM. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Are the repairs complete? | -- | -- | |
Is the resistance reading within the specified values? | 0-5 ohms | |||
20 |
Is the terminal damaged or corroded? | -- | ||
21 | Replace C110. Refer to Wiring Repair . Are the repairs complete? | -- | -- | |
Is the resistance reading within the specified values? | 0-5 ohms | |||
23 | Repair an open condition in CKT 1834 between C110 and the SDM harness connector. Are the repairs complete? | -- | -- | |
24 | Repair an open condition in CKT 1834 between C110 and the sensor harness connector. Are the repairs complete? | -- | -- | |
Is the measured voltage less than the specified value? | 1.0 V | |||
26 |
Are the repairs complete? | -- | -- | |
27 | Reconnect all the SIR system components, make sure all the components are properly mounted. Have all the SIR components been reconnected and properly mounted? | -- | -- | |
28 | Clear all the SIR DTCs. Have all the SIR DTCs been cleared? | -- | -- |