Modules connected to the class 2 serial data circuit monitor for serial data communications during normal vehicle operation. Operating information and commands are exchanged among the modules. When a module receives a message for a critical operating parameter, the module records the identification number of the module which sent the message for State of Health monitoring. A critical operating parameter is one which, when not received, requires that the module use a default value for that parameter. When a module does not associate an identification number with at least one critical parameter within about five seconds of beginning serial data communication, DTC U1000 or U1255 is set. When more than one critical parameter does not have an identification number associated with it, the DTC will only be reported once.
At least one critical operating parameter has not been associated with an identification number within about five seconds after beginning serial data communication.
• | Voltage supplied to the module is in the normal operating voltage range (approximately 9 to 16 volts). |
• | Diagnostic trouble codes U1300 and U1301 do not have a current status. |
• | The vehicle power mode (ignition switch position) requires serial data communication to occur. |
The module uses a default value for the missing parameter.
• | A current U1000 or U1255 will clear when all critical operating parameters for the module have been associated with an identification number or at the end of the current ignition cycle. |
• | A history U1000 or U1255 will clear upon receipt of a scan tool Clear DTCs command. |
When a malfunction (such as an open fuse to a module) occurs while modules are communicating, a Lost Communication DTC is set as a current DTC. When the modules stop communicating (ignition is turned OFF) the current Lost Communication DTC is cleared but the history DTC remains. When the modules begin to communicate again, the module with the blown fuse will not be learned by the other modules so U1000 or U1255 is set current by the other modules. If the malfunction occurs when the modules are not communicating, only U1000 or U1255 is set.
• | Powertrain Control Module/Vehicle Control Module (PCM/VCM) |
• | Automatic Transfer Case (ATC) |
• | Inflatable Restraint Sensing and Diagnostic Module (SDM) |
• | Instrument Cluster (IPC) |
• | Body Control Module (BCM) |
• | Electronic Brake Control Module (EBCM) |
• | Suspension Control Module (SCM) |
• | HVAC Control Module |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Did you record any DTCs in the range of U1001-U1199 with a history status? | -- | |||
Does any module(s) on the class 2 serial data circuit not communicate? | -- | |||
3 | Test the battery positive voltage circuit(s) and the ignition voltage circuit(s) of the module that is not communicating for an open or a short to ground. Refer to Control Module References for the applicable schematic. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | ||
4 |
Did you find and correct the condition? | -- | ||
Did you find and correct the condition? | -- | |||
Test the class 2 serial data circuit of the module that is not communicating for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | |||
Inspect for poor connections at the battery positive voltage circuit(s), the ignition voltage circuit(s), the ground circuit(s), and the class 2 serial data circuit of the module that is not communicating. Refer to Testing for Intermittent Conditions and Poor Connections and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | |||
8 | Replace the module which is not communicating. Refer to Control Module References for the appropriate Repair instructions. Did you complete the replacement? | -- | -- | |
9 |
Does the scan tool display any DTCs which do not begin with a "U"? | -- | Go to Control Module References for the applicable Diagnostic System Check | |
10 | Use the scan tool in order to clear the DTCs. Did you clear the DTCs? | -- | -- | |
Select the Display DTCs function for the module(s) which had U1000 or U1255 set as a current DTC. Does the scan tool display DTCs which do not begin with a "U"? | -- | Go to Control Module References for the applicable Diagnostic System Check | ||
12 | Use the scan tool in order to clear the DTCs. Did you complete the action? | -- | System OK | -- |
Did you record any other DTCs for the module(s) which had U1000 or U1255 set as a current DTC? | -- | Go to Control Module References for the applicable Diagnostic System Check | ||
Does the scan tool display U1000 or U 1255 set as a current DTC? | -- | Go to Diagnostic Aids | ||
15 | Replace the module which had U1000 or U1255 set as a current DTC. Refer to Control Module References for the appropriate Repair Instructions. Did you complete the replacement? | -- | System OK | -- |