Removal Procedure
- Loosen the air cleaner outlet duct clamps
at the following locations:
• | Mass airflow/intake air temperature (MAF/IAT) sensor |
- Remove the radiator inlet hose clip from the outlet duct.
- Remove the air cleaner outlet duct.
- Install a breaker bar
with hex-head socket to the drive belt tensioner bolt.
- Rotate the drive belt tensioner clockwise in order to relieve
tension on the belt.
- Remove the belt from the pulleys and the drive belt tensioner.
- Slowly release the tension on the drive belt tensioner.
- Remove the breaker bar and socket and from the drive belt tensioner
bolt.
- Clean and inspect the belt surfaces of all the pulleys.
Installation Procedure
- Route the drive belt around
all the pulleys except the idler pulley.
- Install the breaker bar with hex-head socket to the belt tensioner
bolt.
- Rotate the belt tensioner clockwise in order to relieve the tension
on the tensioner.
- Install the drive belt under the idler pulley.
- Slowly release the tension on the belt tensioner.
- Remove the breaker bar and socket from the belt tensioner bolt.
- Inspect the drive belt for proper installation and alignment.
Important: Align the arrow at the throttle body end of the duct with the throttle
body attaching stud.
- Install the air cleaner outlet duct.
- Install the radiator inlet hose clip to the outlet duct.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Tighten the air cleaner outlet duct clamps at the following locations:
Tighten
Tighten the air cleaner outlet duct clamp screws to 7 N·m
(62 lb in).