• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Clock B+ | 1 | 1 | -- | -- |
Clock Ground | -- | 1 | 1 | -- |
1. Clock Malfunction |
The instrument panel is equipped with an analog clock. The analog clock utilizes the clock B+ circuit and the clock ground circuit to operate.
Instrument Cluster Description and Operation
Control Module References for scan tool information
⇒ | If greater than the specified value, test the ground circuit for a short to voltage or an open/high resistance. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.