Special Tools
• | J 8001 Dial Indicator Set |
• | J 26900-13 Magnetic Indicator Base |
• | J 35138 Converter End Play Checker |
• | J 39195 Converter End Play Check Tool |
- Inspect the torque converter and replace if any of the following conditions exist:
• | Evidence of damage to the pump assembly. |
• | Metal particles are found after flushing the cooler and cooler lines. |
• | External leaks in the hub area. |
• | Converter pilot is broken, damaged or poor fit into the crankshaft. |
• | Converter hub is scored or damaged. |
• | Internal damage to the stator. |
• | Contamination from engine coolant. |
Note: The torque converter should not be replaced if the fluid has an odor, discoloration or no evidence of metal or clutch plate material.
Flushing the torque converter is not recommended.
- Install the
J 35138 converter end play checker
, the
J 26900-13 indicator base
and the
J 8001 dial indicator set
or
J 39195 end play check tool
to be used with the 300 mm torque converter.
• | The end play for a 245 mm torque converter should be
0-0.38 mm (0-0.015 in). |
• | The end play for a 298 mm torque converter should be
0.1-0.48 mm (0.004-0.019 in). |
• | The end play for a 258 mm and 300 mm torque converter should be
0.1-0.5 mm (0.004-0.020 in). |
- Remove the tools.