Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Has the HVAC Blower Controls System Check been performed? | -- | Go to Step 2 | |
2 |
Does the blower motor run? | -- | Go to Step 3 | Go to Step 4 |
3 | Replace the auxiliary blower motor relay, medium. Refer to Auxiliary Blower Motor Relay Replacement . Is the repair complete? | -- | -- | |
4 |
Is continuity present? | -- | Go to Step 6 | Go to Step 5 |
5 | Replace the auxiliary HVAC control module. Refer to Auxiliary Air Conditioning (A/C) Control Assembly Replacement - Front or Control Assembly Replacement - Auxiliary . Is the repair complete? | -- | -- | |
6 |
Is continuity present? | -- | Go to Step 8 | Go to Step 7 |
7 | Replace the auxiliary blower resistor. Refer to Auxiliary Blower Motor Resistor Replacement . Is the repair complete? | -- | -- | |
8 | Connect a J 39200 (volts) between cavity 1 of the high relay socket and ground. Is battery voltage present? | -- | Go to Step 10 | Go to Step 9 |
9 | Locate and repair the open in CKT 542 (RED) between cavity 1 of the auxiliary blower relay, medium and splice S401. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
10 | Locate and repair the open in CKT 1925 (RED) between the auxiliary blower motor relay, medium and the auxiliary HVAC control modules. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- |