Endgate Rattle
- Open the
endgate (3) to the full horizontal position.
- Continue to hold the endgate handle open to assure that the latch
rods are completely recessed on both sides of the endgate.
- Remove the rubber bumper (1) on the left
hand side by sliding it back on the bracket. Make sure that the thicker surface
of the rubber bumper is facing forward, this will be the opposite direction
from the original position.
- Close the endgate and evaluate the rattle with the rubber bumper
(1) rotated 180 degree on the left hand side only.
- If the endgate continues to rattle repeat these procedures for
the right hand side.