- Install the checkballs (2-6,
8, 12) in the valve body and retain checkballs with J 36850
or an equivalent.
- Install the valve body
over the J 25025-5
Guide
Pins, and connect the manual valve link to the manual valve.
- Install two bolts to hold the valve body in place.
- Remove the J 25025-5
.
- Install the fluid level
indicator stop bracket (93) and the valve body bolts (62) that
are shown only.
- Finger tighten the bolts.
- Inspect the Transmission
Fluid Pressure (TFP) Manual Valve Position Switch Assembly for the following
conditions:
• | Damaged or missing O-rings |
- Install the TFP manual
valve position switch (69) and bolts (62, 70).
- Inspect the wiring harness
solenoid assembly for the following conditions:
- Install the transmission wiring harness on the valve body.
- Install the TCC solenoid valve and bolts (68).
Important: You must tighten certain bolts in a spiral pattern as indicated by the
arrows. If you tighten these bolts at random you may distort valve bores.
This will inhibit valve operation.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
Important: Tighten certain bolts in a spiral pattern as indicated by the arrows.
If you tighten these bolts at random you may distort valve bores. This will
inhibit valve operation.
- Tighten the bolts in the order shown.
Tighten
Tighten the bolts to 11 N·m (8 lb ft).
Each bolt number refers to a specific bolt size, as indicated by the
following list:
- Install the TCC PWM solenoid valve (396) and the solenoid
retainer (395).
- Connect all electrical connectors (1-6) to the electrical
components.