Caution: Allow the engine to cool before servicing the secondary air injection AIR system in order to reduce the chance of severe burns.
5.1. | Install a vacuum pump to the nipple side of the check valve, AIR pump side. |
5.2. | Pump the vacuum pump to 10 inches Hg and observe the gauge. |
5.3. | Replace the check valve if the vacuum bleeds down to zero within 5 seconds. |
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the check valve to the AIR pipe to 23N·m (17 lb ft)
Tighten
Tighten the AIR pipe to the exhaust manifold to 20N·m (15 lb ft).