Removal Procedure
- Release the clamp (4)
securing the AIR hose to the AIR pump assembly base.
- Release the clamp (5) securing the AIR hose to the AIR
pump shut-off valve.
- Remove the AIR hose from
the AIR pump shut-off valve outlet port (3).
- Remove the vacuum line (5) from the vacuum port (4) of
the AIR pump shut-off valve.
- Release the AIR pump shut-off valve inlet port (1) from
the AIR pump outlet hose.
Installation Procedure
- Install the AIR pump shut-off
valve inlet port (1) to the AIR pump outlet hose.
- Install the vacuum line (5) to the AIR pump shut-off valve
vacuum port (4).
- Install the AIR hose to the AIR pump shut-off valve inlet port (3).
- Install the clamp (5)
securing the AIR hose to the AIR pump shut-off valve.
- Install the clamp (4) securing the AIR hose to the AIR
pump assembly base.