Table 1: | Body Control Module |
Table 2: | Heating and Air Conditioning |
Table 3: | Rear Auxiliary Climate Module |
Table 4: | Rear HVAC |
Table 5: | Engine |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F) | |||
Left Solar Sensor | Data | Counts | Varies |
Right Solar Sensor | Data | Counts | Varies |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F) | |||
A/C Switch | Input/Output | On/Off | Off |
AC Permission | Input/Output | Withheld/Granted | Varies |
Air Inlet Door Actual | Door Positions | Counts | Varies |
Air Inlet Door Commanded | Door Positions | Counts | Varies |
Air Inlet Motor Drive | Door Positions | Stop/Increase/Decrease | Stop |
Air Mix Door Left Commanded | Door Positions | Counts | Varies |
Air Mix Door Right Commanded | Door Positions | Counts | Varies |
Auto Switch | Input/Output | On/Off | Off |
Battery Voltage | Input/Output | Volts | 13.5-14.5 V |
Blower Motor PWM Speed | Door Positions | Percent | 12-114% |
Engine Coolant Temp | Sensor Data | °C/°F | Varies |
Fan Down Button | Input/Output | On/Off | Off |
Fan Up Button | Input/Output | On/Off | Off |
Front Defrost Switch | Input/Output | On/Off | Off |
Ign. Since Current DTC | Input/Output | Numeric | 0 Cycles |
Inside Air Temp. Sensor | Sensor Data | °C/°F | Varies |
Inside Air Temp. Fan | Sensor Data | On/Off | On |
Left Mix Door Actual | Door Positions | Counts | Varies |
Left Mix Motor Drive | Door Positions | Stop/Increase/Decrease | Stop |
Left Temp. Setting | Input/Output | °C/°F | Varies |
LH AC Duct Actual | Sensor Data | Counts | Varies |
LH AC Duct Desired | Sensor Data | Counts | Varies |
LH Heater Duct Actual | Sensor Data | Counts | Varies |
LH Heater Duct Desired | Sensor Data | Counts | Varies |
Mode Door Actual | Door Positions | Counts | Varies |
Mode Dr. Motor Command | Door Positions | Counts | Varies |
Mode Motor Drive | Door Positions | Stop/Increase/Decrease | Stop |
Mode Select Position | Door Positions | Off/Auto/Defrost/Heater/Htr./Def./Bi-Level/Panel | Varies |
Mode Switch | Input/Output | On/Off | Off |
Off Switch | Input/Output | On/Off | Off |
Outside Air Temp. Filtered | Input/Output | °C/°F | 22-27°C (70-80°F) |
Outside Air Temp. Raw | Input/Output | °C/°F | Varies |
Pressure Cycle Switch | Input/Output | Low Pressure/Normal | Varies |
Recirculate Switch | Input/Output | On/Off | Off |
RH AC Duct Actual | Sensor Data | Counts | Varies |
RH AC Duct Desired | Sensor Data | Counts | Varies |
RH Heater Duct Actual | Sensor Data | Counts | Varies |
RH Heater Duct Desired | Sensor Data | Counts | Varies |
Right Mix Door Actual | Door Positions | Counts | Varies |
Right Mix Motor Drive | Door Positions | Stop/Increase/Decrease | Stop |
Right Temp. Setting | Input/Output | °C/°F | Varies |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F) | |||
Air Temp. Switch Pos. | Front Aux. Controls | Numeric | Varies |
Ambient Air Temp. Sensor | Data | °C/°F | Varies |
Aux. Temp Dr. Motor Command | Door Positions | Counts | Varies |
Aux. Temp Dr. Motor Status | Door Positions | Stop/Increase/Decrease | Stop |
Aux. Temp Dr. Position | Door Positions | Counts | Varies |
Battery Voltage | Data | Volts | 13.5-14.5 Volts |
Blower Switch Pos. | Front Aux. Controls | Numeric | Varies |
Engine Coolant Temp. | Data | °C/°F | Varies |
Ign. Since Current DTC | Data | Cycles | 0 Cycles |
Inside Air Temp. Fan | Input/Output | On/Off | On |
Inside Air Temp. Sensor | Data | Counts | Varies |
Lower Heater Duct Actual | Data | Counts | Varies |
Mode Door Actual | Door Positions | Counts | Varies |
Mode Motor Drive | Door Positions | Stop/Increase/Decrease | Stop |
Mode Dr. Motor Command | Door Positions | Counts | Varies |
Mode Switch Pos. | Front Aux. Controls | Numeric | Varies |
Rear HVAC Fan Select Pos. | Input/Output | Auto/Off/Low/Med/High | Auto |
Rear HVAC Mode Select Pos. | Input/Output | Auto/Floor/Bi-Level/Panel | Auto |
Upper Htr. Duct Actual | Data | Counts | Varies |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F) | |||
Battery Voltage | Data | Volts | 13.5-14.5 Volts |
Ign. Since Current DTC | Data | Cycles | 0 Cycles |
Rear HVAC Fan Down Sw. | Data | Active/Inactive | Inactive |
Rear HVAC Fan Speed | Data | Auto/Off/Low/Med/High | Auto |
Rear HVAC Fan Up Switch | Data | Active/Inactive | Inactive |
Rear HVAC Mode Switch | Data | Active/Inactive | Inactive |
Rear HVAC Motor Pos. | Data | Off/Auto/Lower/Bi-Level/Upper | Varies |
Rear Temp. Select Sw. | Data | Up/Down/Inactive | Inactive |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F) | |||
A/C Pressure Sensor | Engine Data 2 | kPa/psi | 629-845 kPa (85-120 psi) |
A/C Pressure Sensor | Engine Data 2 | Volts | Varies |
A/C Relay Command | Engine Data 2 | On/Off | Varies |
A/C Request Signal | Engine Data 2 | Yes/No | Varies |
ECT Sensor | Engine Data 2 | °C/°F | 92°C (197°F) |