- Install
the checkballs (2-6, 8, 12) in the valve body and retain checkballs
with
J 36850
or an equivalent.
- Install the valve body over the
J 25025-5
Guide Pins, and connect the manual valve link to the manual valve.
- Install two bolts to hold the valve body in place.
- Remove the
J 25025-5
.
- Install the fluid level indicator stop
bracket (93) and the valve body bolts (62) that are shown only.
- Finger tighten the bolts.
- Inspect the Transmission Fluid Pressure
(TFP) Manual Valve Position Switch Assembly for the following conditions:
• | Damaged or missing O-rings |
• | Poor terminal retension |
• | Sediment in switch membrane |
- Install the TFP manual valve position
switch (69) and bolts (62, 70).
- Inspect the wiring harness solenoid
assembly for the following conditions:
• | Poor terminal retension |
- Install the transmission wiring harness
on the valve body.
- Install the TCC solenoid valve and bolts (68).
Important: You must tighten certain bolts in a spiral
pattern as indicated. If you tighten these bolts at random you may distort valve
bores. This will inhibit valve operation.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Tighten the bolts in the order shown.
Tighten
Tighten the bolts to 11 N·m (8 lb ft).
Each bolt number refers to a specific bolt size, as indicated by the following
list:
- Install the TCC PWM solenoid valve (396)
and the solenoid retainer (395).
- Connect all electrical connectors (1-6)
to the electrical components.