The numbers below refer to the step numbers on the diagnostic table.
This step tests for auxiliary blower motor that does not operate from the front auxiliary HVAC control assembly regardless of the desired blower motor speed.
This step tests for a auxiliary blower motor that operates, yet does not accurately respond to the desired blower motor speed from the front auxiliary HVAC control assembly.
This step tests for an inoperative auxiliary mode actuator in one mode positions or in the wrong mode positions from the front auxiliary HVAC control module.
This step tests for an inoperative auxiliary mode actuator in one mode positions or in the wrong mode positions from the console HVAC control module.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air does not flow correctly from the auxiliary air distribution outlets. | |||
1 | Did you review the HVAC operation and perform the necessary inspections? | Go to Step 2 | |
2 |
Is the auxiliary blower motor OFF? | Go to Step 3 | Go to Blower Motor Always On |
Place the front auxiliary control assembly blower switch in each speed position. Does the auxiliary blower motor operate at all? | Go to Step 4 | Go to Blower Motor Inoperative | |
Does the auxiliary blower motor operate correctly for each speed position? | Go to Step 5 | Go to Blower Motor Malfunction | |
Does the auxiliary mode actuator operate correctly for each mode position? | Go to Step 6 | Go to Step 7 | |
Does the auxiliary mode actuator operate correctly for each mode position? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 10 | |
7 | Test the mode door control - auxiliary circuit of the front auxiliary HVAC control assembly for an open, a high resistance or a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 8 |
8 |
Does the resistance change between each selected mode position? | Go to Step 10 | Go to Step 9 |
9 | Inspect for poor connections at the harness connector of the front auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 11 |
10 | Inspect for poor connections at the harness connector of the auxiliary HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 12 |
11 | Replace the front auxiliary HVAC control assembly . Refer to Rear Seat Audio Control Replacement in Entertainment. Did you complete the replacement? | Go to Step 13 | -- |
12 | Replace the auxiliary HVAC control module. Refer to Control Module References in Computer/Integrating Systems for replacement, setup, and programming. Did you complete the replacement? | Go to Step 13 | -- |
13 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |