Subject: | Passenger Safety Belt Reminder Light Remains On After Remote Start (Perform Appropriate Corrective Action Below)) |
Models: | 2007 Cadillac Escalade, Escalade ESV, Escalade EXT |
2007 Chevrolet Avalanche, Suburban, Tahoe |
2007 GMC Yukon, Yukon XL, Yukon Denali, Yukon Denali XL |
with Remote Start (RPO AP3) |
Some customers may comment that the passenger safety belt reminder light remains on with the passenger seatbelt buckled after a remote start.
This condition may be caused by a software anomaly within the SDM.
It is important that you first identify the calibration number that is in the SDM. This can be done using the Tech 2® and requesting module ID. The calibration number will determine if the SDM calibration can be updated or if the SDM will need to be replaced before the new calibration can be installed. Use the table below to identify the proper corrective action that is required.
Calibration ID | Corrective Action |
---|---|
15854648 | Reprogram the SDM using SPS and Perform Module Setup Procedure. DO NOT Replace SDM |
15871382 | Reprogram the SDM using SPS and Perform Module Setup Procedure. DO NOT Replace SDM |
15871383 | Reprogram the SDM using SPS and Perform Module Setup Procedure. DO NOT Replace SDM |
15925929 | Replace the SDM, Reprogram using SPS and Perform Module Setup Procedure |
15925928 | Replace the SDM, Reprogram using SPS and Perform Module Setup Procedure |
15925927 | Replace the SDM, Reprogram using SPS and Perform Module Setup Procedure |
If the vehicle has one of the current production calibrations listed below, DO NOT replace the SDM and DO NOT reprogram. If a problem still exists, it is not caused by a calibration error. Use normal diagnostics to correct the condition.
Calibration ID | Corrective Action |
---|---|
15926442 | Calibration is Current, No Update is Needed. Follow Normal Diagnostics to Correct the Condition |
15926441 | Calibration is Current, No Update is Needed. Follow Normal Diagnostics to Correct the Condition |
15926440 | Calibration is Current, No Update is Needed. Follow Normal Diagnostics to Correct the Condition |
The new calibrations are currently available in TIS version 6.0 (or later) or on TIS2WEB.
For vehicles repaired under warranty, use only one of the following labor operations:
Labor Operation | Description | Labor Time |
---|---|---|
C8817 | Replace SDM (Includes Time for Programming and Setup) | Use Published Labor Operation Time |
N9559* | Reprogram SDM using SPS (Includes Time to Identify Current Software ID and Setup Module) | 0.5 hr |
* This is a unique labor operation number for use only with this bulletin. This number will not be published in the Labor Time Guide. |