Removal Procedure
- Remove
negative battery cables.
- Remove the electrical connector from the solenoid.
- Remove the vacuum hoses.
- Remove the solenoid mounting
bolt
- Remove the wastegate solenoid.
Installation Procedure
- Install the wastegate
solenoid.
- Install the wastegate mounting bolt.
- Install the vacuum hoses.
- Install the electrical connector.
- Install the negative battery cables.