Removal Procedure
- Remove the electrical
connector from the ESO
solenoid.
Important: Remove any debris from the ESO mounting surfaces on the injection pump
before servicing the ESO Solenoid. This will prevent contaminate intrusion
into the injection pump.
- Remove the ESO solenoid.
Installation Procedure
- Install the new o-ring
on the ESO solenoid.
- Install the ESO solenoid in the injection pump.
Tighten
Tighten solenoid (external hex or internal hex) to 25 N·m
(19 lb ft).
- Install the ESO electrical connector.
- Start engine and check for leaks.