The powertrain control module (PCM) supplies a bias voltage approximately 450 mV, on the heated oxygen sensor (HO2S) signal high and low signal circuits. When you turn the ignition to the ON position, battery voltage is supplied to the HO2S heater. As the heater reaches the operating temperature, the HO2S voltage responds by changing from a bias voltage range to the normal operation. Typically, as the HO2S reaches the operating temperature, the HO2S voltage goes from a bias voltage to a voltage below 300 mV. Depending on the exhaust gas content, the HO2S voltage can go above 450 mV.
The PCM runs the heater test only on a cold start, depending on the cumulative air flow, and only once an ignition cycle. When you start the engine, the PCM monitors the HO2S voltage. When the HO2S voltage goes above or below the bias range threshold, the PCM determines how much time this process took. If the PCM detects that the process took too much time for the HO2S to enter into normal operating range, a diagnostic trouble code (DTC) sets. The time the process takes the HO2S to reach operating temperature is based on the amount of air that flows into the engine.
• | DTCs P0101, P0102, P0103, P0106, P0107, P0108, P0112, P0113, P0117, P0118, P0121, P0122, P0123, P0300, P0351, P0401, P0404, P0405, P0440, P0442, P0446, P0452, P0453, P1258, P1404, P1441 are not set. |
• | The IAT sensor and the ECT sensor are less than 50°C (122°F), and are within 8°C (14.5°F) of each other at engine start-up. |
• | The ignition 1 signal is between 11 volts and 18 volts. |
• | The MAF sensor is less than 22 g/s. |
• | The HO2S at engine start up is between 425 mV and 475 mV. |
• | The scan tool is disconnected. |
The HO2S voltage remains inactive for a predetermined period of time.
• | The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records. |
• | The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A current DTC, Last Test Failed, clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Clear the MIL and the DTC with a scan tool. |
Important: Remove any debris from the PCM connector surfaces before servicing the PCM. Inspect the PCM connector gaskets when diagnosing or replacing the PCM. Ensure that the gaskets are installed correctly. The gaskets prevent water intrusion into the PCM.
• | Use the Freeze Frame/Failure Records in order to help locate an intermittent condition. If you cannot duplicate the DTC, the information in the Freeze Frame/Failure Records can help to determine how many miles have occurred since the DTC set. The Fail Counter and the Pass Counter can also help determine how many ignition cycles the diagnostic reported a pass or a fail. In order to isolate when the DTC failed, operate the vehicle within the same Freeze Frame conditions such as RPM, load, vehicle speed, temperature, etc. that you observed. For an intermittent condition, refer to Symptoms - Engine Controls . These conditions include: |
- | The RPM |
- | The vehicle load |
- | The vehicle speed |
- | The temperature |
• | The heater diagnostic will only run on a cold start and run once per ignition cycle. |
• | An oxygen supply inside the HO2S is necessary for proper operation. The HO2S wires provide the supply of oxygen. Inspect the HO2S wires and inspect the connections for breaks or for contamination. Refer to Heated Oxygen Sensor (HO2S) Wiring Repairs in Wiring Systems. |
The numbers below refer to the step numbers on the diagnostic table.
Allow the engine to cool before you perform this test. If the sensor is at the operating temperature, the HO2S voltage will stay high or low. If the HO2S voltage stays between 300-700 mV, the HO2S heater is inoperative.
If more than one HO2S DTC is set, the HO2S fuse may be open. Test all the related circuits going to all the heated oxygen sensors for a short to ground. If you cannot locate a shorted circuit, it may be necessary to disconnect each HO2S one at a time in order to locate a shorted sensor.
This step tests whether an Ignition 1 positive voltage supply is available at the sensor.
This step tests whether a ground is available at the sensor.
This step tests whether the HO2S heater element is internally open.
Inspect the Ignition 1 positive voltage circuits at the underhood electrical center for poor connections.
Test the ground circuits for an open if more than one heater DTC sets.
Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: Engine Controls Schematics | ||||
1 | Did you perform the Diagnostic System Check-Engine Controls? | -- | Go to Step 2 | |
Important: If DTC P0300 is set, diagnose that DTC first. Refer to Diagnostic Trouble Code (DTC) List . Important: Allow the engine to cool for one-half hour before proceeding with this table.
Does the HO2S voltage go from a bias voltage to above or below the specified range? | 300-700 mV | Go to Diagnostic Aids | Go to Step 3 | |
Inspect the HO2S fuse for an open. Is the HO2S fuse open? | -- | Go to Step 11 | Go to Step 4 | |
Does the test lamp illuminate? | -- | Go to Step 5 | Go to Step 7 | |
Connect the test lamp between the HO2S ignition 1 voltage and the HO2S heater ground. Does the test lamp illuminate? | -- | Go to Step 6 | Go to Step 8 | |
Measure the resistance between the HO2S ignition 1 voltage and the HO2S heater ground at the HO2S pigtail using the DMM. Is the HO2S resistance within the specified range? | 3.5-14.0 ohms | Go to Step 9 | Go to Step 10 | |
Repair the open in the HO2S ignition 1 voltage circuit to the HO2S. Refer to Heated Oxygen Sensor (HO2S) Wiring Repairs in Wiring Systems. Did you complete the action? | -- | Go to Step 12 | -- | |
Repair the open in the HO2S heater ground circuit. Refer to Heated Oxygen Sensor (HO2S) Wiring Repairs in Wiring Systems. Did you complete the action? | -- | Go to Step 12 | -- | |
9 |
Did you find and repair the condition? | -- | Go to Step 12 | Go to Step 10 |
10 | Replace the HO2S. Refer to Heated Oxygen Sensor Replacement - Bank 1 Sensor 1 . Did you complete the action? | -- | Go to Step 12 | -- |
11 |
Did you complete the action? | -- | Go to Step 12 | -- |
12 |
Does the DTC run and pass? | -- | Go to Step 13 | Go to Step 2 |
13 | With a scan tool, observe the stored information, Capture info. Does the scan tool display any DTCs that you have not diagnosed? | -- | System OK |