Blower Motor Control Module Replacement for Generic Unit Repair 2006
Removal Procedure
- Remove the right side instrument panel (I/P) insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gages, and Console.
- Disconnect the electrical connector from the blower control module.
- Remove the 2 heat stakes from the blower control module using a small chisel.
- Remove the blower control module.
Installation Procedure
- Install the blower control module.
Notice: Refer to Fastener Notice in the Preface section.
- Install the 2 new screws in the pre-drilled holes to the side of the heat stakes in the blower control module and the HVAC module assembly.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Connect the electrical connector to the blower control module.
- Install the right side I/P insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gages, and Console.
- Refer to
Control Module References
for programming and setup information.