Tools Required
• | J 43600 ACR 2000
Air Conditioning Service Center |
• | J 42220 Universal
12V Leak Detection Lamp |
Important: Flushing with the ACR 2000 is not intended
to remove metal from the A/C system.
Flushing is intended to remove the following:
• | Desiccant, following a desiccant bag failure |
• | Refrigerant contamination |
Important: Warmer engine or ambient temperature decreases
the refrigerant recovery time during the A/C flush procedure.
- Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging
.
- Remove the orifice tube. Refer to
Expansion (Orifice) Tube Replacement
.
- Connect the A/C lines with the orifice tube removed.
- Remove the A/C compressor. Refer to
Air Conditioning Compressor Replacement
.
- Install J 45268-5 to the A/C discharge hose.
- Install J 45268-4 to the A/C suction hose.
- Forward flow refrigerant flushing is recommended
for contaminated refrigerant or PAG oil.
Perform the following procedure:
| Important: The filter inside J 45268-1 is serviceable.
Remove and discard the check valve from the filter.
|
7.1. | Service the filter with ACDelco P/N GF 470, before each flush. |
Connect J 45268-1 flush filter to the suction port of J 45268
-4 flush adapter.
7.2. | Install the blue hose from J 43600
to J 45268-1 flush filter adapter. |
7.3. | Install the red hose from J 43600
to J 45268-5. |
- Reverse flow refrigerant flushing is recommended for desiccant bag failure
only.
Perform the following procedure and replace the accumulator when
the flush is complete:
| Important: The filter inside J 45268-1 is serviceable.
Remove and discard the check valve from the filter.
|
8.1. | Service the filter with ACDelco P/N GF 470, before each flush. |
Connect the J 45268-1 flush filter to the discharge port of the J 45268-5
flush adapter.
8.2. | Install the blue hose from J 43600
to J 45268-1 flush filter adapter. |
8.3. | Install the red hose from J 43600
to the suction port of J 45268-4. |
Important: Close the valve on the external refrigerant
tank, before starting the flush process.
- Flush the A/C system. Follow the instructions supplied with the J 43600
.
- Remove J 45268-4 from the A/C suction hose.
- Remove J 45268-5 from the A/C discharge hose.
Important: Flushing will remove all the PAG oil from
the A/C system.
The A/C system must be replenished with the correct amount
of PAG oil.
- Drain the PAG oil from the A/C Compressor. Rotate the compressor input shaft
to assist in draining the PAG oil from the compressor.
- Add back the total system capacity of PAG oil to the A/C compressor. Refer
to
Refrigerant System Capacities
.
Important: Flushing will remove the fluorescent leak
detection dye from the A/C system.
- Add one bottle of J 41447
directly to the A/C compressor.
- Install the A/C compressor. Refer to
Air Conditioning Compressor Replacement
.
- Inspect the orifice tube for debris. Clean or replace as needed.
- Install the orifice tube. Refer to
Expansion (Orifice) Tube Replacement
.
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fittings using the J 42220
.