Tools Required
J 39400-A
Halogen Leak
Detector
Removal Procedure
- Recover the refrigerant from the system. Refer to
Refrigerant Recovery and Recharging
.
- Remove the air cleaner. Refer to
Air Cleaner Assembly Replacement
in Engine Controls -- 6.0 L.
Important: The nuts (4) and the ferrules (3) will remain on the evaporator
tube. Do not try to remove.
- Remove the nuts (4) from the A/C refrigerant filter (1).
- Remove the A/C refrigerant filter (5)
from the evaporator tube (4).
Installation Procedure
- Coat the O-rings (2) with 525 viscosity refrigerant oil.
- Install the O-rings (2) to the evaporator tube.
- Install the A/C refrigerant filter (3)
to the evaporator tube (2) with the flow arrow pointing towards the evaporator.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the nuts (4) to the A/C refrigerant filter (1).
Tighten
Tighten the nuts to 15 N·m (11 lb ft).
- Recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fittings of the repaired or reinstalled component using
the J 39400-A
.
- Install the air cleaner. Refer to
Air Cleaner Assembly Replacement
in Engine Controls -- 6.0 L.