Instrument Panel Inflatable Restraint Module Switch Replacement for HUMMER H2 2003
Removal Procedure
Caution: Refer to SIR Caution in the Preface section.
- Remove the instrument panel trim bezel. Refer to
Instrument Cluster Trim Panel Replacement
in Instrument Panel, Gages and Console.
- Remove the I/P module switch from the lower
right opening of the switch plate panel.
- Disconnect the I/P module switch electrical connector.
Installation Procedure
- Connect the I/P module switch electrical connector.
- Install the I/P module switch into the
lower right opening of the switch plate panel.
- Install the instrument panel trim bezel. Refer to
Instrument Cluster Trim Panel Replacement
in Instrument Panel, Gages and Console.