Subject: | Vehicle is Difficult to Fill with Fuel or Filling Station Pump Shuts Off Before Tank is Full (Inspect Fuel Tank Vent Tube Opening and Replace Fuel Tank) |
Models: | 2003 HUMMER H2 |
Some customers may comment that their vehicle is difficult to fill with fuel or when filling, the pump continuously shuts off before the tank is full.
This condition may be caused by the fuel filler tank vent opening being collapsed inside the tank, which does not allow fuel vapors to vent sufficiently.
This condition may cause the fuel fill nozzle to shut off prematurely.
Inspect the fuel filler tank vent for blockage and replace the fuel tank if an obstruction is encountered using the procedure listed below.
Part Number | Description |
---|---|
15191462 | Fuel Tank |
Parts are currently available from GMSPO.
For vehicles repaired under warranty, use:
Labor Operation | Description | Labor Time |
---|---|---|
L1260 | Inspect Fuel Filler Tank Vent | 0.3 hr |
In Other Labor Hours, add 1.5 hr for replacing fuel tank. Authorization Required. |