Subject: | New Suspension Position Calibration Procedure Added |
Models: | 2003-2005 HUMMER H2 |
This bulletin is being issued to add the Suspension Position Calibration procedure in the Air Suspension sub-section of the Service Manual.
The following information has been updated within SI. If you are using a paper version of this Service Manual, please make a reference to this bulletin on the affected page.
A new essential tool has been developed and shipped to all North American dealers for the H2 air suspension system. These Suspension Position Calibration Blocks, CH-47816, are to be used during the suspension position calibration procedure.
This procedure noted below should be performed after compressor assembly, air suspension control module, or suspension position sensor replacement. Uneven suspension position can also be corrected by performing this procedure.
Important: Before proceeding with the steps below, ensure:
• There are no stored diagnostic trouble codes stored in the ASCM. • The vehicle is on level ground. • There are no occupants in the vehicle. • The tire pressures are at the recommended kPa/psi.