Subject: | Revised Recirculation Actuator Replacement |
Models: | 2003-2006 HUMMER H2 |
This bulletin is being issued to revise the Recirculation Actuator Replacement procedure in the HVAC Systems-Automatic sub-section of the Service Manual. Please replace the current information in the Service Manual with the following information.
The following information has been updated within SI. If you are using a paper version of this Service Manual, please make a reference to this bulletin on the affected page.
Recirculation Actuator Replacement
Removal Procedure
- Remove the instrument panel (I/P) upper trim pad. Refer to Trim Pad Replacement -- Instrument Panel (I/P) Upper.
- Disconnect the electrical connector from the recirculation actuator.
- Remove the screws from the recirculation actuator (1).
- Remove the recirculation actuator (1) from the HVAC module assembly (2).
Installation Procedure
- Install the recirculation actuator (1) to the HVAC module assembly (2).
Notice: Refer to Fastener Notice in Cautions and Notices.
- Install the screws to the recirculation actuator (1).
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Connect the electrical connector to the recirculation actuator.
- Install the I/P upper trim pad. Refer to Trim Pad Replacement -- Instrument Panel (I/P) Upper.
- Reprogram the recirculation actuator. Refer to Re--Calibrating Actuators .