Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor is inoperative in all speed positions. | ||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |
2 |
Does the blower motor operate in any of the speed positions? | -- | Go to Blower Motor Malfunction | Go to Step 3 |
3 |
Does the test lamp illuminate? | -- | Go to Step 10 | Go to Step 4 |
4 |
Does the test lamp illuminate? | -- | Go to Step 8 | Go to Step 5 |
5 | Connect a test lamp between the battery positive voltage circuit of the blower motor control processor and a good ground. Does the test lamp illuminate? | -- | Go to Step 7 | Go to Step 6 |
6 | Repair the battery positive voltage circuit of the blower motor control processor. Refer to Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 16 | -- |
7 | Repair the ground circuit of the blower motor control processor. Refer to Wiring Repairs . Did you complete the repair? | -- | Go to Step 16 | -- |
8 |
Does the test lamp increase intensity when the blower speed is increased? | -- | Go to Step 11 | Go to Step 9 |
9 | Test the blower motor speed control circuit of the blower motor control processor for an open, short to ground, or short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 12 |
10 | Inspect for poor connections at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 13 |
11 | Inspect for poor connections at the harness connector of the blower motor control processor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 14 |
12 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 15 |
13 | Replace the blower motor. Refer to Blower Motor Replacement . Did you complete the replacement? | -- | Go to Step 16 | -- |
14 | Replace the blower motor control processor. Refer to Blower Motor Control Processor Replacement . Did you complete the replacement? | -- | Go to Step 16 | -- |
15 | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 16 | -- |
16 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |