Removal Procedure
- Remove the I/P carrier. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gages and Console.
- Disconnect the electrical connector (4)
from the right air temperature actuator (3).
- Remove the screws from the right air temperature actuator (3).
- Remove the right air temperature actuator (3) from the HVAC module
assembly (2).
Installation Procedure
- Install the right air temperature actuator (3)
to the HVAC module assembly (2).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws to the right air temperature actuator (3).
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Connect the electrical connector to the right air temperature actuator.
- Install the I/P carrier. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gages,
and Console.
- Reprogram the air temperature actuator. Refer to
Actuator Recalibration
.