GM Service Manual Online
For 1990-2009 cars only

Removal Procedure

  1. Loosen the air cleaner outlet duct clamps from the throttle body.
  2. Loosen the air cleaner outlet duct clamps from the mass airflow sensor.
  3. Remove the air cleaner outlet duct.

  4. Object Number: 801113  Size: SH
  5. Remove the radiator inlet hose from the fan shroud retainer (3).
  6. Remove the bolt (5) from the fan shroud (3).
  7. Remove the transmission oil cooler line from the fan shroud retainer.
  8. Rotate the slip ring from under the fan shroud.

  9. Object Number: 801107  Size: SH
  10. Remove the bolts (4) from the fan shroud (3).
  11. Remove the fan shroud (3) from the vehicle.

Installation Procedure


    Object Number: 801107  Size: SH
  1. Install the fan shroud (3) to the vehicle.
  2. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  3. Install the bolts (4) to the fan shroud (3).
  4. Tighten
    Tighten the bolts to 9 N·m (80 lb in).

  5. Install the transmission oil cooler line to the fan shroud retainer.
  6. Rotate the slip ring to the original position.
  7. Install the bolt (5) to the fan shroud (3).
  8. Tighten
    Tighten the bolt to 5 N·m (44 lb in).


    Object Number: 801113  Size: SH
  9. Install the radiator inlet hose to the fan shroud retainer (3).
  10. Install the air cleaner outlet duct.
  11. Tighten the air cleaner outlet duct clamp at the throttle body.
  12. Tighten
    Tighten the clamp screw to 7 N·m (62 lb in).

  13. Tighten the air cleaner outlet duct clamp at the mass airflow sensor.
  14. Tighten
    Tighten the clamp screw to 7 N·m (62 lb in).