Removal Procedure
- Remove the I/P insulator panel. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel, Gages and Console.
- Disconnect the electrical connector (1)
from the left air temperature actuator (2).
- Remove the screws from the left air temperature actuator (2).
- Remove the left air temperature actuator (2) from the HVAC module
assembly (3).
Installation Procedure
- Install the left air temperature actuator (2)
to the HVAC module assembly (3).
Notice: Refer to Fastener Notice in the Preface section.
- Install the screws to the left air temperature actuator (2).
Tighten
Tighten the screws to 2 N·m (18 lb ft).
- Install the electrical connector (1) to the left air temperature
actuator (2).
- Install the I/P insulator panel. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel, Gages,
and Console.
- Reprogram the air temperature actuator. Refer to
Actuator Recalibration
.