The ambient light sensor is a light sensitive transistor that sends a variable voltage signal to the body control module (BCM) in response to the exterior light level. The BCM energizes the daytime running lamp (DRL) relay by grounding the DRL relay control circuit. The DRL operate when the ambient light sensor indicates daytime, the ignition switch is in the RUN position, and the gear selector is not in the park position.
This diagnostic procedure supports the following DTC:
DTC B2600 Daytime Running Lamp Control
The battery voltage must be between 9-16 volts.
• | When the BCM sends a DRL OFF command and the DRL relay control circuit is shorted to ground. |
• | When the BCM sends a DRL ON command and the DRL relay control circuit is shorted to voltage or open. |
The DRL will not operate or will remain always on.
• | This DTC will clear on current status after the condition for setting the fault is corrected. |
• | A history DTC will clear after 100 consecutive ignition cycles without a fault present. |
• | History and current DTCs can be cleared using a scan tool. |
The numbers below refer to the step numbers on the diagnostic table.
Listen for an audible click when the DRL relay operates. Command both the ON and OFF states. Repeat the commands, as necessary.
This step tests for voltage at the coil side of the DRL relay.
This step verifies that the BCM is providing ground to the DRL relay.
This step tests if ground is constantly being applied to the DRL relay.
This step tests if there is opposing voltage present or an open in the DRL relay control circuit.
After replacement of the BCM, you must calibrate the new module for proper operation.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Headlights/Daytime Running Lights (DRL) Schematics Connector End View Reference: Lighting Systems Connector End Views or Data Communication Connector End Views | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |
Does the DRL relay turn ON and OFF with each command? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 | |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 10 | |
Does the test lamp turn ON and OFF with each command? | Go to Step 8 | Go to Step 5 | |
Does the test lamp remain illuminated with each command? | Go to Step 7 | Go to Step 6 | |
Test the control circuit of the DRL relay for high resistance, an open, or a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 9 | |
7 | Test the control circuit of the DRL relay for a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 9 |
8 | Inspect for poor connections at the DRL relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 11 |
9 | Inspect for poor connections at the harness connector of the body control module (BCM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 12 |
10 | Repair the DRL supply voltage circuit of the DRL relay. Refer to Wiring Repairs . Did you complete the repair? | Go to Step 13 | -- |
11 | Replace the DRL relay. Refer to Relay Replacement . Did you complete the replacement? | Go to Step 13 | -- |
Replace the BCM. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 13 | -- | |
13 |
Does the DTC reset? | Go to Step 2 | System OK |