- Install the right temperature door (2) to the upper HVAC module case (1).
- Install the upper HVAC module case (1) to the lower HVAC module case (2).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws to the HVAC module assembly.
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Install the wiring harness to the HVAC module assembly.
- Install the lower recirulation housing (1) to the HVAC module assembly (2).
- Install the screws to the lower recirulation housing (1).
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Install the upper recirulation housing (1) to the HVAC module assembly (2).
- Install the screws to the upper recirulation housing (1).
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Install the air distribution housing (1) to the HVAC module assembly (2).
- Install the screws to the air distribution housing (1).
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Install the wiring harness to the air distribution housing (1).
- Install the mode actuator (4) to the HVAC module assembly (1).
- Install the screws to the mode actuator (4).
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Connect the electrical connector (3) to the mode actuator (4).
- Install the HVAC module assembly. Refer to
HVAC Module Assembly Replacement
.