Removal Procedure
- Loosen the air cleaner outlet duct clamps at the following locations:
• | Mass airflow/intake air temperature (MAF/IAT) sensor |
- Remove the air cleaner outlet duct.
- Install a breaker bar with hex-head socket to the drive belt tensioner bolt.
- Rotate the drive belt tensioner clockwise in order to relieve tension on the belt.
- Remove the belt from the pulleys and the drive belt tensioner.
- Slowly release the tension on the drive belt tensioner.
- Remove the breaker bar and socket and from the drive belt tensioner bolt.
- Clean and inspect the belt surfaces of all the pulleys.
Installation Procedure
- Route the drive belt around all the pulleys except the idler pulley.
- Install the breaker bar with hex-head socket to the belt tensioner bolt.
- Rotate the belt tensioner clockwise in order to relieve the tension on the tensioner.
- Install the drive belt under the idler pulley.
- Slowly release the tension on the belt tensioner.
- Remove the breaker bar and socket from the belt tensioner bolt.
- Inspect the drive belt for proper installation and alignment.
Note: Align the arrow at the throttle body end of the duct with the throttle body attaching stud.
- Install the air cleaner outlet duct.
Caution: Refer to Fastener Caution in the Preface section.
- Tighten the air cleaner outlet duct clamps at the following locations:
Tighten
Tighten the air cleaner outlet duct clamp screws to 7 N·m (62 lb in).