Step | Action | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Exterior Lights Schematics Connector End View Reference: Lighting Systems Connector End Views | |||||||||||||
1 | Did you review the Exterior Lighting Systems Description and Operation and perform the necessary inspections? | Go to Step 2 | |||||||||||
2 | Verify that the stop lamps are always ON. Do the stop lamps operate normally? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 | ||||||||||
3 | Disconnect the stop lamp switch. Do the stop lamps remain illuminated? | Go to Step 4 | Go to Step 5 | ||||||||||
4 | Test for a short to voltage in one of the following circuits or components. Refer to Wiring Repairs .
Did you find and correct the condition? | Go to Step 7 | Go to Step 6 | ||||||||||
5 | Replace the stop lamp switch. Refer to Stop Lamp Switch Replacement . Did you complete the repair? | Go to Step 7 | -- | ||||||||||
6 | Replace the body control module (BCM). Refer to Control Module References for replacement, setup, and programming. Did you complete the repair? | Go to Step 7 | -- | ||||||||||
7 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |